Worked solution from the Metals MCQ booklet.
Galvanising means coating iron with zinc.
The zinc coating covers the iron, so it keeps out air and water. This is barrier protection.
Zinc is also more reactive than iron, so if the coating is scratched, the zinc corrodes first. This is sacrificial protection.
So both types are provided.
So the answer is B.
A is wrong because galvanising is a coating, not an alloy. C and D each leave out one of the two types.
▶ Whole paper
Video solution of the whole paper · by CHEMISTRY WITH SIR FARHAN KHAN. Tap the picture to open it on YouTube.