Cambridge AS Level Biology 9700 · 11.2 Antibodies and vaccination

Q36 · 9700/22/M/J/25 Q6

Worked solution from the Immunity Theory (Paper 2) booklet, Part 2 of 2.

Q369700/22/M/J/25original Q6Structured · 10 marks
Question 6 from 9700/22/M/J/25

Worked solution

(a)

A non-competitive inhibitor lowers Vmax but the curve keeps the same shape. Km is the substrate concentration at half of the new Vmax.

Draw a smooth curve (not S-shaped) that starts to branch away below the original curve before the third plotted point (2 arbitrary units), and levels off at a lower maximum rate. Make sure it passes through 0.055 to 0.06 mmol dm−3 on the x-axis at half of its own maximum. [1]

Read off your curve: half of your Vmax is reached at about Km = 0.055 to 0.06 mmol dm−3 [1]

(b)

Write: a start codon is a triplet (three) of bases on the mRNA (or DNA) that begins translation, for example AUG, which codes for methionine (the first amino acid). [1]

Write: a stop codon is a triplet of bases that ends translation. It does not code for an amino acid, so no more amino acids are added and the polypeptide is released from the ribosome (examples UAA, UAG, UGA). [1]

(c)(i)

After step 5, only detection antibody that is bound to toxin stays in the well.

Draw a detection antibody attached to each toxin (on the toxin, not on the capture antibody). Do not draw any loose antibody. [1]

(c)(ii)

Write any one: the two antibodies bind to different sites (epitopes) on the toxin; or the detection antibody has HRP (enzyme) attached but the capture antibody does not; or the capture antibody is immobilised (fixed to the well) but the detection antibody is free. [1]

(c)(iii)

Any four of these points.

A colorimeter measures the absorption of light by the reaction mixture. [1]

A paler (lighter) blue-green colour gives a lower absorbance reading, and a deeper colour gives a higher reading. [1]

A lower intensity of colour shows a lower concentration of oxidised TMB, so a lower concentration of toxin. [1]

A low toxin concentration still gives a different absorbance reading from the negative (blank) result, whereas the eye may not tell colourless from very pale blue-green, so the colorimeter is not subjective. [1]

Extra points that also score: use standards / a calibration curve to find the actual concentration; acid stops the reaction so only a small amount of TMB is oxidised when HRP is low.

KEY IDEAA non-competitive inhibitor lowers Vmax but does not change Km, and a colorimeter turns colour intensity into a number so a weak positive can be told from a negative.
TOTAL 10 marks

Official mark scheme

Mark scheme for 9700/22/M/J/25 question 6
VIDEO
▶ Whole paper

Video solution of the whole paper · by Hasvora Education. Tap the picture to open it on YouTube.

Solutions follow the official Cambridge mark schemes; marks are shown in grey. Videos are from other YouTube channels. Paper codes read component / series / year: M/J = May/June, O/N = October/November. Past-paper questions © UCLES, reproduced for classroom practice.