Worked solution from the Reaction kinetics MCQ booklet.
We follow the colour of I2 with a colorimeter. The rate of reaction at 20 s is the gradient of the concentration against time curve at 20 s. The graph given is absorbance against time, so we change absorbance into concentration first.
The calibration graph is a straight line through the origin. At absorbance 0.5 the concentration is 0.25 × 10−3 mol dm−3. So concentration = 0.5 × 10−3 × absorbance.
Draw a tangent to the absorbance curve at 20 s. It falls by about 0.2 to 0.3 absorbance units over about 30 s, so the gradient is about 0.008 to 0.01 absorbance units per second.
Rate = gradient × 0.5 × 10−3 = about 4 to 5 × 10−6 mol dm−3 s−1
The closest answer is 5 × 10−6 mol dm−3 s−1.
So the answer is A.
B is about double the value. C and D are hundreds of times too big. They come from using absorbance values as if they were concentrations, or from forgetting the 10−3 factor.
▶ Whole paper
Video solution of the whole paper · by ChemBridge. Tap the picture to open it on YouTube.
Solutions follow the official Cambridge mark schemes. Videos are from other YouTube channels. Paper codes read component / series / year: M/J = May/June, O/N = October/November. Past-paper questions © UCLES, reproduced for classroom practice.