5070/11/M/J/21 question 1: worked solution (May/June 2021, paper 11)
Show as plain textHide plain text
Cambridge O Level Chemistry 5070 · 12.1 Experimental design Worked solution from the Experimental techniques and chemical analysis MCQ booklet. Q3 5070/11/M/J/21 original Q1 Multiple choice Worked solution We need to measure 28.2 cm³ of solution. The apparatus must be accurate to 0.1 cm³. A beaker (A) is only a rough guide. A pipette (C) measures one fixed volume, usually 25.0 cm³, so it cannot give 28.2 cm³. A measuring cylinder (D) is less accurate and is read to about 1 cm³, so it cannot show 28.2 exactly. A burette (B) can deliver any volume and is read to 0.1 cm³, so it can give 28.2 cm³. So the answer is B . A , C and D are wrong for the reasons above. KEY IDEA Use a burette to measure variable volumes accurately. A pipette gives one fixed volume, and a measuring cylinder is less accurate. ANSWER B VIDEO ▶ Starts at Q1 (0:24) Starts at Q1 (0:24) · by Lucid Mind. Tap the picture to open it on YouTube.