5070/11/O/N/24 question 39: worked solution (October/November 2024, paper 11)
Show as plain textHide plain text
Cambridge O Level Chemistry 5070 · 12.3 Chromatography Worked solution from the Experimental techniques and chemical analysis MCQ booklet. Q31 5070/11/O/N/24 original Q39 Multiple choice Worked solution The chromatogram shows only three spots, but there are four dyes. So two of the dyes are at the same height and cannot be told apart. Dyes that overlap can be pulled apart by running the chromatogram in a different solvent . Different dyes dissolve to different extents in the new solvent, so they move different distances. A Measuring Rf values does not separate dyes that are at the same height. B Running for longer will not separate them, because the solvent front is already near the top of the paper and the two dyes would still travel together. D A locating agent is only for colourless substances, but these dyes are already coloured. So the answer is C . A , B and D are wrong for the reasons above. KEY IDEA If spots overlap in chromatography, try a different solvent. Different substances dissolve to different extents in it. ANSWER C VIDEO ▶ Whole paper Video solution of the whole paper · by Sir Rehan. Tap the picture to open it on YouTube.